Accession number;01A0231214
|
| Title;Accuracy of k0-factors for neutron induced prompt gamma-ray analysis. |
| Author;
MATSUE HIDEAKI
(Japan At. Energy Res. Inst., Tokai Res. Establ.)
YONEZAWA CHUSHIRO
(Japan At. Energy Res. Inst., Tokai Res. Establ.)
|
Journal Title;Abstracts of Papers. Symposium on Radiochemistry
|
Journal Code:F0139B
|
ISSN:1345-2762
|
|
VOL.44th;NO.;PAGE.57(2000)
|
| Figure&Table&Reference; |
| Pub. Country;Japan |
| Language;Japanese |
| Abstract;The k0 standardization method has been studied and applied to many kinds of standard reference materials at JAERI for the accurate determination of multielements by neutron-induced prompt gamma-ray analysis. Up to now, the k0-factors for 27 elements using Cl as a comparator have been measured by the cold and thermal neutron guided beams of JRR-3M. In this study, we evaluated the accuracy of the k0 factors by the following manners. 1) The obtained k 0-factors were compared with those obtained with thermal neutron guided beam at the Institute of Isotope and Surface Chemistry (IKI) in Hungary. 2) The k0-factors were compared with those calculated by using the evaluated thermal neutron capture gamma-ray data (Z<21) from the LBNL (Lawrence Berkeley National Laboratory, USA)-IKI and the Lone's table. (author abst.) |
|
|
|
Related Articles;
|