Accession number;03A0061351
|
| Title;The motion analysis from kneeling down to deepbending after the artificial knee joint placement technique using the fluorometry. |
| Author;
KANEKASU KOICHI
(Toyamakensaiseikai Takaokabyoin Riumachise)
HONJO SHIGERU
(Toyamakensaiseikai Takaokabyoin Riumachise)
NAKADA MASAYA
(Toyamakensaiseikai Takaokabyoin Riumachise)
KATO HIROMI
(Toyamakensaiseikai Takaokabyoin Riumachise)
BANKS S A
(Biomotion Foundation, Fl, Usa)
|
Journal Title;Nippon Jinko Kansetsu Gakkaishi
|
Journal Code:L0423A
|
ISSN:0913-3968
|
|
VOL.32;NO.;PAGE.95-96(2002)
|
| Figure&Table&Reference;FIG.2, TBL.1, REF.8 |
| Pub. Country;Japan |
| Language;Japanese |
| Abstract;Using the fluoroscopy equipment, the kinematics over 140 angles of bend degree in kneeling downmotion was examined.It was examined for 21 artificial knee joint placement techniques (cement use, 3 monthes progress, 145 degree angles of bend) of rear capsulectomy combined use. In the deep bending, there was tibia inner rotating of the average of 7.9 and largest 17.5 degrees.Good femur rollback from the 90 degrees to largest angle of bend was shown.The inner rollback movement was less than outer.As a surface separation in inserts and femur, the lift-off was recognized in the bending motion. |
|
|
|