Study of Bad-Smell Sensing Using Gas Detector Tube

Accession number;04A0637696
Title;Study of Bad-Smell Sensing Using Gas Detector Tube
Author; TANAKA YUKINOBU (Tokyo Inst. of Technol.) YOSHIOKA MASAHIRO (Tokyo Inst. of Technol.) NAKAMOTO TAKAMICHI (Tokyo Inst. of Technol.) MORIIZUMI TOYOSAKA (Tokyo Inst. of Technol.)
Journal Title;Transactions of the Institute of Electrical Engineering of Japan. E
Journal Code:L3098A
ISSN:1341-8939
VOL.124;NO.9;PAGE.321-326(2004)
Figure&Table&Reference;FIG.10, REF.4
Pub. Country;Japan
Language;Japanese
Abstract;In this study, offensive odor was sensed in gas detecting tube. Concretely, the experimental results on methyl mercaptan detector and hydrogen sulfide detector tube were described. Using the gas detecting tube, not only concentration at a certain time but also continuous concentration change at the real time can be observable. The gas detecting tube measured the concentration until now by visual observation, however in this case, the automatic reading was enabled and the reduction of read-out error was realized.