Separation and Determination of Trace Amounts of Aluminium(III), Vanadium(V), Iron(III), Copper(II) and Nickel(II) with CALKS and PAR by RP-HPLC

Accession number;05A0362062
Title;Separation and Determination of Trace Amounts of Aluminium(III), Vanadium(V), Iron(III), Copper(II) and Nickel(II) with CALKS and PAR by RP-HPLC
Author; PENG JINGDONG (Southwest China Normal Univ., Chongqing, Chn) LIU SHAOPU (Southwest China Normal Univ., Chongqing, Chn) DENG CHUANYUE (Southwest China Normal Univ., Chongqing, Chn)
Journal Title;Anal Sci
Journal Code:G0673B
ISSN:0910-6340
VOL.21;NO.3;PAGE.259-262(2005)
Figure&Table&Reference;FIG.7, TBL.1, REF.25
Pub. Country;Japan
Language;English
Abstract;An RP-HPLC method for the separation and determination of aluminium(III), vanadium(V), iron(III), copper(II) and nickel(II) with CALKS (Chromazol KS) and PAR ([4-(2-pyridylazo)resorcinol]) chelating on a YWG-ODS column was developed. A mixture of methanol-tetrahydrofuran(THF)-water (60:5:35 v/v) containing 0.2 mol/L LiCl, 5 * 10-5 mol/L CALKS, 5 * 10-5 mol/L PAR and acetate buffer solution (pH 4.9) was selected as mobile phase. The method has high sensitivity, with the detection limits being 6 ng/mL for aluminium(III), 3.5 ng/mL for vanadium(V), 10.4 ng/mL for iron(III), 6.3 ng/mL for copper(II) and 8.7 ng/mL for nickel(II). It also has good selectivity, so that most foreign metal ions do not interfere under the optimum conditions. The method can be applied to the simultaneous determination of trace amounts of aluminium, vanadium, iron, copper and nickel in rice and flour samples. (author abst.)
FULLTEXT