New JIS mark certification system and calibration of thermal conductivity for thermal insulation materials

Accession number;07A0043243
Title;New JIS mark certification system and calibration of thermal conductivity for thermal insulation materials
Author; FUJIMOTO TETSUO (Japan Testing Center for Construction Materials, JPN) TASAKA TAICHI (Japan Testing Center for Construction Materials, JPN) HAGIHARA SHINJI (Japan Testing Center for Construction Materials, JPN)
Journal Title;Thermophys Prop
Journal Code:X0031A
ISSN:0911-1743
VOL.27th;NO.;PAGE.121-123(2006)
Figure&Table&Reference;FIG.3, TBL.4, REF.2
Pub. Country;Japan
Language;Japanese
Abstract;In measurement of thermal conductivity of thermal insulation materials, the uncertainty of thermal conductivity measurement is decided by 4 factors mainly. They are (1) heat flow through specimens, (2) thickness measurement of specimens, (3) measuring area, (4) temperature measurement. In these factors temperature measurement has a great effect to uncertainty of thermal conductivity measurement. We investigated a measurement method of temperature so that the uncertainty became smaller. As a result the uncertainty of thermal conductivity measurement changed into 1.5% from 2.5%. In Japan, JIS mark certification system was revised at October 2005. Before JIS mark certification system was revised a nation had licensed to indicate JIS mark to factories. So JIS mark certification system was revised accredited certification bodies license to indicate JIS mark instead of a nation. In this report new JIS mark certification system and standard materials of thermal conductivity for thermal insulation were introduced. (author abst.)